Schroder Reference Tonearm User Manual |
|
|
|
|
|
|
|
4.2) Mounting your cartridge
The cartridge can be mounted in the headshell using the supplied M2.5 non.magnetic stainless stell screws (b). You might prefer to first seperate the mounting plate from the armwand by unscrewing the M3-connection-screw (c) .
Usually it is sufficient to tighten the M2.5 screws well, but not excessively so. Overtightened screws can result in internal tensions in the cartridge body, negatively affecting the sound or even damaging the internal structure. Don’t forget: the next step after "REALLY tight" is "totally loose".
Connecting the mounting plate with the armwand requires tightening screw c, the same rules apply. |
|
4.3) Tracking force and overhang
Take the counterweight and slide it onto the back section of the armwand. Leave your "stylus cover" (if your cartridge features such a device) on and set the tracking force to approx. 1.5 gr. Tighten the counterweight set screw (d) just so that you can still slide the counterweight without applying much pressure.
Using a proper template (i.e. Dennesen or the one that comes with the arm) the overhang is now adjusted by rotating the entire armbase around it’s central post after loosening the overhang-locking-screw (a). Using the aforementioned alignment gauges will automatically result in achieving a proper "outer" zero-point (120.9mm) once you have managed to get the "inner" zero-point(66.04mm) right.
The overhang-locking-screw (a) should be tightened now.
Next, check the tangency of the cantilever as seen from above – with the stylus not quite touching the alignment gauge – and, if neccessary, turn the headshell mounting plate after loosening screw (c) in the right direction.
Finally, tighten screw (c) again. |
|
4.4) VTA-adjustment
As a starting point you should raise or lower the tonearmblock until the armwand appears to be parallel to the record surface with the needle in the groove.
Just unscrew the VTA-set screw (f) une full turn, insert a 3mm Allen key into the center hole and turn the (hidden) VTA-adjustment screw (g) clockwise to lower the arm or counterclockwise to raise the arm (make shure that the Allen key caught the screw).
Don’t forget to tighten the VTA-set screw (f) again.
This adjustment is NOT to be carried out during play!
You can use your Allen key and it’s position relative to the four screw heads holding the top plate of the armbase as a gauge/reminder how far you’ve turned it. One full turn alters the VTA by 0.7mm. |
|
4.5) Antiskating
To compensate for the skatingforce turn the antiskating-adjustment-disc (h) counterclockwise to increase force (initially, several turns might be required!) and clockwise to reduce it. A good compromise will be achieved once mistracking occurs in both channels simultaneously while playing the tracking ability test tracks on the ORTOFON test record (0002 or 0003). In case you have no access to any such test record just put the diamond on the space between the leadout grooves (or a "blank" record, i.e. Cardas sweeper record) and adjust antiskating until the arm/cartridge combo wanders slowly towards the center of the record.
From then on, use your ears... |
|
4.6) Adjusting the gap between the magnets
With a decent light source placed behind your record player it is easy to make out (and control) the gap between the magnets which facilitates friction-free movement of the tonearm.
The distance between the magnets determines the effectiveness of damping both tonearm/cartridge resonance and "parasitic" energy, generated by the cartridge or the turntable.
The smaller the gap the higher the damping and vice versa.
The gap between the magnets is altered by first inserting a 1.5mm Allen key into the set screw (i) , sitting in the middle of disc (h). You then hold the Allen key steady while turning the disc clockwise to widen the gap or counterclockwise to close it.
This sounds a lot more difficult than what it is..
The gap should be at least 0.3mm wide, enough to allow for a common business card to be slid in without to much resistance.
If the magnets were to touch each other during play the resulting friction would cause the cartridge to skip.
The suspension thread used has an extremely high tensile strength, a very hard surface and will not deteriorate over time.
It does stretch (break in) though over a period of two weeks max. (usually, it takes three days only). Once it has set, only under extreme conditions (very high temperatures + high humidity) can the thread exhibit a tendency to "give" a little more. So check the gap after a summer thunder storm (no more stretching after three of those). |
|
4.7) Silicon damping or not
The arm features the option to use silicon oil (i.e.SME2013) to dampen the tonearm resonance – predominantly in the axis of the armwand – resulting in a reduction of the "wiggliness" commonly associated with unipivot tonearms. This has almost no bearing(pun intended) on the tonearm/cartridge resonance whicht is a function of the eff. mass of the arm, the compliance of the cartridge and it’s mass.
Simply dip a piece of non-magnetic wire (brass, copper...) into the silicon fluid, wait until a drop has formed and wipe it off onto the thread (near it’s upper end). The drop will slowly travel down the thread until it finally vanished in the small oil well where the thread enters the armwand. Repeat until you’re satisfied with the sonic results (do not overfill). Common silicon fluid has no adverse effect on the thread or the bearing in general, excess fluid can be wiped off using a cotton swab.
The effect resulting from that procedure depends upon the cartridge used and usually increases perceived "blackness" between notes and solidity of images without sacrificing "attack" and "air". Some cartridges (recent Lyras for example) sound better without any additional damping. |
|
5) The "Finetuning"
Everyone who has to mount cartridges frequently understands the importance of precisely adjusting an arm/cartridge combination to release it’s full potential.
Overhang, azimuth, VTA, tracking force and, if featured, variable damping of the arm movement are all important parameters.
The overhang adjustment was described already, nevertheless let me add that a single "perfect" overhang setting does not exist. Should you own a lot of records that are cut close to the inner groove you might consider using 63mm instead of 66mm as your inner "zero point" – many crescendo finales of symphonic works could be tracked with reduced distortion this way.
On the other hand exist a lot of "pop"-records with no modulation, but leadout groove already where the "inner" zero point is located. One doesn’t even benefit from this second distorsion minimum..
Correct overhang adjustment results in max. tracing-error-related tracking distortion of barely more than 0.6% for an arm with 239mm eff. length, 0.47% for a 305mm arm. |
|
|
|
|
Fine adjustment is
achieved by inserting a narrow blade (<3mm) -screwdriver into the hole on the
right side of the counterweight (hold the armwand with two fingers while
doing this), then turning the internal grub screw (A in the photo above) inward or outward,
altering the counterweight’s center of gravity ever so slightly. Please
refer to the photo above, "B" is where the grub screw is located. This
adjustment covers a range of no more than +/- 1.5°. This should suffice to
compensate for minor misalignments of the stylus/cantilever assembly. Starting with the armwand parallel to the record surface, VTA adjustment can be carried out in small steps (i.e. 0.2mm, ~ a quarter turn of the Allen key) until the best separation between individual instrument in space, the least amount of "grain" audible and the best integration of fundamentals and upper harmonics is achieved. |
|
There is no "perfect" position, varying record thicknesses and a different cutting angle used for most records made before 1965 neccesitate a new setting for every other record. Stylus shapes are also more or less susceptible to changes in the VTA – the "sharper" the stylus, the more sensitive to changes..) The more time you spend on adjusting the VTA the less you’ll get to actually enjoy your records.
The tracking force determines the tracking ability and also the position of the coils in the magnetic generator. Follow the manufacturer’s recommendation and try increasing or lowering the tracking force by increments of 0.1gr. Low frequency tracking ability shouldn’t be lower than 70my. Soundwise more relevant is the high frequency tracking ability. The appropriate tracks on the Shure TT115 test record are helpful to get closer to the optimal tracking force. |
|
The damping is , as already mentioned, a function of the distance between the magnets, or, more precisely, the flux density in the gap between the magnets.
It is to be adjusted so that the lower registers will be reproduced with control and heft without loosing the resolution of high frequency fine detail and "air".
Overdamping this arm is close to impossible (often the case with silicone fluid damped arms) but rarely does the smallest gap result in the most satisfying sound.
The amount of tightening of any of the arm’s screws has an influence on the energy transmission and therefore dissipation and should be experimented with.
Generally speaking, only screws a, l and f should be tightened well. Screws b, c, and d require some experimentation.
Oh,.. and leave the screw underneath the lower magnet alone. Once you’ve loosened it , the magnets require realignment for which the arm needs to be send back to me. |
|
Should you have any questions regarding mounting/adjusting or technical details of this tonearm, feel free to contact me via phone or email.
Equally welcome is any sort of criticism or suggestions for improvements.
Yours truly Frank Schröder |
|
|
|